Our Products

The meter is a Class 1.0 Accuracy electric energy metering instrument with the high manufacturing technology to realize the measurement and control of active energy, and it supports the standard DLMS/COSEM specification, to realize the interoperability under master station.The meter mainly includes measurement unit, display unit, button unit, real-time clock unit, function of infrared and Bluetooth communication with other auxiliary ports that can be programmable.
  • Peak Shaving
  • Load Shifting
  • Energy Management
  • Renewable Integration
Fluke 83V and 87V Digital Multimeters is For all detailed specifications.Accuracy is given as ±([% of reading] + [number of least significant digits]) at 18 °C to 28 °C, with relative humidity up to 90 %, for a period of one year after calibration. For Model 87 in the 41⁄2-digit mode, multiply the number of least significant digits (counts) by 10. AC conversions are ac-coupled and valid from 3 % to 100 % of range. Model 87 is true-rms responding. AC crest factor can be up to 3 at full scale, 6 at half scale. For non-sinusoidal wave forms add -(2 % Rdg + 2 % full scale) typical, for a crest factor up to 3.
SNV-EFI earth fault indicator, it Widely used in various ring cabinets, high/ Medium or low -voltage switch gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type ofpower grid in the Low/medium voltage network. The use of cable type grounding fault indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and theefficiency of fault handling. The design uses electromagnetic induction, and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability
  • EV Charging Stations
  • Parking Facilities
  • Highway Charging Hubs
  • Fast Charging Support
  • Renewable Energy Integration
  • Modular Expansion
  • Remote Monitoring
  • Lithium Iron Phosphate Technology
  • Long Service Life
DLIM-412 Industrial 4.0 Technology Application Training System is one engineer teaching system following the latest industrial 4.0 technology, it may be used for TVET vocational school to realize training projects like MOUDLEBUS communication between PLC and RFID; Profinet communication between PLC and PLC; Communication between MES and PLC; Application of bus communication technology; Application of motor drive technology; Mechatronics collaborative simulation: mechanical interference, mechanism kinematics etc.
Overhead type Line Fault Indicators is based on the sensor that through Current Transformer (CT) to get the line current signal through smart processor and calculation to judge the short circuit or ground fault. The sensor ablet to warn the user through red LED equipped. It is beneficial for power management to find the fault points and to help in restoring the faulty line faster.
Next generation three phase fully programmable smart energy meter with robust performance of high accuracy, high reliability, wide measurement range, and low power consumption, etc. The meter is fully compliant with IEC 62052-11:2020, IEC62053-21:2020, IEC62053-23:2020 and IEC62052-31:2016, OIML and DLMS/COSEM standards, allowing billing and management applications in IEC compliant countries for residential, commercial and industrial energy measurement and management.A Transformer Operated measurement (CT Connected) meter, covering wide voltage range of AC active/reactive energy with frequency of 50/60Hz. It can provide bi-directional communication with advanced information to utility data management system and end-customer, It can be read locally using HHU via optical port, as well as remotely via modular communication channel of PLC/RF/GPRS/GSM/LTE/NB-IOT installed in meter body under a sealable cover and connected to meter mainboard thru serial port, which make it possible for remote data access by DCU or MDCS. It also supports to control an External circuit breaker (ECB) via Output relay or RS-485 (Using RJ-45 connector) over MODBUS. The meter is designed with a built-in GPS modem which can triangulate signal from GPS satellite to position the location of the meters installed and push to the HES.
The Sonel MIC-5001 functional insulation resistance meter is a reliable tool for measuring insulation resistance up to 5 TΩ. Due to its excellent performance, it is used in a wide range of applications, including industry, railway industry and housebuilding industry. The device combines a number of advantages – it is handy, has an ergonomic shape and a robust casing with a high level of protection. In addition, it is characterised by low battery power consumption, and it is possible to recharge the batteries even during measurements.
The Sonel MIC-5010 insulation resistance meter is a reliable tool for measuring insulation resistance up to 15 TΩ. The maximum measurement current is 1.2 mA or 3 mA, which guarantees the charging of an object with a large capacity in a short time. Each measurement, whether the programmed time expires or is manually interrupted, ends with the meter discharging the object. The device has unique algorithms that allow it to recognise the nature of the voltage present on the object, thanks to which the instrument can determine whether the voltage is the mains voltage – in which case the measurement will not be carried out – or whether it is the voltage generated by an electromagnetic field – in which case the measurement will be carried out. This makes it possible to carry out measurements in the presence of very strong electromagnetic fields where this was previously not feasible.The instrument is equipped with accessories which guarantee safety during measurements with all available voltages – both test leads, probes and crocodile clips meet extremely rigorous standards (guaranteed voltage strength up to 11 kV for test leads and 5.5 kV for crocodile clips and test probes). The accessories are supplied as standard with a handy carrying case. The high resistance of the device to interference means that cables as long as 20 m can be used for measurements.